Compressed Air Monitoring Instruments

Compressed air measuring Instruments are used in measuring various parameters in compressed air and other gases such as to check or detect leakage, Dew point of the compressed air/ gases & also check for Flow in the line according to ISO 8573.

Stationary Dew Point Measurement in Compressed Air Systems

Stationary Dew Point Measurement in Compressed Air Systems
  • Stationary Dew Point Measurement in Compressed Air Systems
Ask For Price
Product Price :Get Latest Price

Product Details:

Model Name/NumberDP 400,FA 510
Usage/ApplicationDew point monitoring for refrigeration & absorption dryers
Measuring Range80...20 DegreeCtd resp. -20...50 DegreeCtd
Moisture Parameters4 to 20 mA 0 to 10 V,Pt 100,Pt 1000
Pressure Range-1 to 50 bar,special version up to 350 bar
Features3.5" graphic display,easy operation with touch screen & 2 alarm contacts (230 VAC,3 A) pre & main

Stationary dew point measurement in compressed air systems :- Stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the measured values. 2 alarm relays are available for monitoring of threshold values. Available either with a classic analogue output 4...20 mA or optionally with digital interfaces like Ethernet and RS 485 (Modbus protocol). As a stand-alone solution the measured data stored in the1 optional data logger can be read-out via USB stick and evaluated by means of the software CS Soft Basic.
Request
Callback
Yes! I am interested

Dew Point Sensor with Integrated Display and Alarm Relay

Dew Point Sensor with Integrated Display and Alarm Relay
  • Dew Point Sensor with Integrated Display and Alarm Relay
Ask For Price
Product Price :Get Latest Price

Product Details:

Model Name/NumberFA 500
Usage/ApplicationFor refrigeration driers and desiccant driers
Measuring Range80...20 DegreeCtd,-60...30 DegreeCtd,-20...50 DegreeCtd,resp.. 0...100% RH
Moisture Parameters+/- 1 DegreeC to +50...-20 DegreeCtd +/- 2 DegreeC to -20...-50 DegreeCtd +- 3 DegreeC to -50...-80 DegreeCtd
Pressure Range-1...50 bar special version up to 500 bar
FeaturesSensor diagnosis on site with a portable device or CS Service Software,Integrated display Pressure

Dew point sensor with integrated display and alarm relay:- the ideal dew point measuring instrument for refrigeration, membrane and adsorption dryers. The threshold value can be easily adjusted via the keypad.
Request
Callback
Yes! I am interested

Flow Meter for Heavy Duty Industrial Applications

Flow Meter for Heavy Duty Industrial Applications
  • Flow Meter for Heavy Duty Industrial Applications
Ask For Price
Product Price :Get Latest Price

Product Details:

Usage/ApplicationNatural gas, biogas, methane, nitrogen, argon and carbon dioxide.
Model Name/NumberVA 520,VA 500,VA 550 and VA 570
Measuring Range90 l/min,90 m3/h,170 m3/h,290 m3/h,530 m3/h,730 m3/h,1195 m3/h,2050 m3/h,2840 m3/h.
Measuring SectionFrom 1/2 inch to DN 400/ DN 500.
FeaturesRemovable measuring head,Screwing with centering device,Screwing with centering device

Flow meter for heavy duty Industrial applications are also ideal for conversion or retrofitting and for new installations of gas meters, compressed air meters, flow meters, etc. to existing or new energy management software according to DIN ISO 50001 and DIN ISO 16247 and building management systems.

The M-Bus meters have been metrologically improved and completely revised and in addition to the mandatory M-Bus interface also have the following additional outputs and bus systems:

Modbus RTU, Modbus TCP or TCP PoE, Profibus, Profinet, 4..20 mA and pulse Hard (in preparation).

Request
Callback
Yes! I am interested

Portable Flow Meter

Portable Flow Meter
  • Portable Flow Meter
Ask For Price
Product Price :Get Latest Price

Product Details:

Usage/ApplicationUsed in compressed air/ gas application e.g-Flow measurement, Pressure, vacuum measurement etc.
Measuring Range (Sensor VA 520)90 m3/h, 170 m3/h, 290 m3/h, 530 m3/h, 730 m3/h, 1195 m3/h, 2050 m3/h, 2840 m3/h
Measuring Range (Sensor VA 550)759 l/min, 89 m3/h, 148 m3/h, 148 m3/h, 366 m3/h, 600 m3/h, 1028 m3/h, 1424 m3/h, 2644 m3/h and more
Model Name/NumberPI 500
Features3.5" graphic display, easy operation via touch screen, Integrated data logger for storage.

Portable flow meter: Those flow meters in which any sensor which is having insertion probe can be used with a portable datalogger (PI 500) to detect the flow. Flow sensor which can be used are  VA 500 / VA 520.

The graphic indication of coloured measurement curves is inimitably. Up to 100 million measured values can be stored with date and name of measuring site. The measured values can be transferred to the computer by means of a USB stick. The data can be comfortably evaluated with the CS Soft Basic software. Measured data and service reports can be issued easily and quickly.
Request
Callback
Yes! I am interested

Portable Dew Point Meter

Portable Dew Point Meter
  • Portable Dew Point Meter
Ask For Price
Product Price :Get Latest Price

Product Details:

Model Name/NumberDP 500/ 510
Usage/ApplicationCompressed air: Examination of refrigeration, membrane, adsorption dryers, Residual moisture etc.
Measuring Range-80 upto +50 Degree C and -20 upto +70 Degree C
Moisture Parameters & Pressure Rangeg/m3,mg/m3,ppm V/V,g/kg,Degree Ctd atm,%rF & -1 to 50 bar standard -1 to 350 special version
FeaturesEasy operation via touch screen,Integrated data logger for storage of the measured values

Portable Dew Point Meter: DP 510 it is possible to performing all measuring tasks with one instrument. It disposes of all functions of DP 500 and has an additional freely assignable sensor input. Additionally to the internal dew point measurement one further optional sensor can be connected. So you could meet nearly all industrial measuring tasks.
Request
Callback
Yes! I am interested

Mobile Dew Point Measurement with Pressure Sensor

Mobile Dew Point Measurement with Pressure Sensor
  • Mobile Dew Point Measurement with Pressure Sensor
Ask For Price
Product Price :Get Latest Price

Product Details:

Usage/ApplicationIndustrial application For measurement of all humidity parameters under pressure up to 16 bar.
Model Name/NumberDP 400
Measuring Range-80...+50 DegreeCtd -20...+70 DegreeC 0...100 % rF 0...16 bar +/- 0,5 %
Moisture Parameters & Pressure Rangeg/m3,mg/m3,ppm V/V,g/ kg,DegreeCtd atm,% rF & +/-1 DegreeC bei 50 to -20 DegreeCtd +/- 2 DegreeC bei -20 and more
FeaturesDew point measurement down to -80 DegreeCtd,Robust case for field use,Integrated pressure measurement

Mobile Dew Point Measurement with Pressure Sensor:- The portable dew point meter with integrated, rechargeable battery has been developed especially for the field use. Besides a highly precise dew point sensor the device also contains a precise pressure sensor up to 16 bar. So in addition to the dew point in °Ctd, the temperature in °C and the line pressure in bar also further moisture parameters can be calculated.
Request
Callback
Yes! I am interested

Leak Detector with Integrated Camera

Leak Detector with Integrated Camera
  • Leak Detector with Integrated Camera
Ask For Price
Product Price :Get Latest Price

Product Details:

Usage/ApplicationLeak detection in Compressed air, gas, steam and vacuum systems, steam traps, seals etc.
Model Name/NumberLD 500/ 510
Working Frequency40 kHz +/- 2 kHz
Sensitivity RangeMin: 0.1 l/min at 6 bar,0 to 25 m distance
FeaturesPhoto of Leakage, cost of leakage, Size of leakage in l/m

LD 500/ 510 with integrated camera and leakage calculation are ideal measuring instruments which help to find and document even smallest leakages(0.1 l/m) easily even from far distances. It can also auto adapts the sensitivity automatically to the environment and eliminates the ambient noise reliably. and comes with a USB Interface to transmit the report easily and to create a report according to ISO 50001.

Following accessories are available depending on the distance of the leakage:

Focus Tip-upto 0.5m

Goose neck- upto 0.5m.

Acoustic Trumphet->0.5- 6m.

Parabolic mirror- >6- 25m.

CS leak detector software can create reports for ISO 50001 with image of leakage, rate of leakage in l/m, cost of leakage per year & carbon footprint.

Request
Callback
Yes! I am interested

LD 400 Leak Detector

LD 400 Leak Detector
  • LD 400 Leak Detector
Ask For Price
Product Price :Get Latest Price

Product Details:

Usage/ApplicationCompressed air lines, gas, vapour and vacuum plants and door seals
Model Name/NumberLD 400
Working Frequency40 kHz +/- 2 kHz
Sensitivity RangeMin: 0.1 l/min at 6 bar, 5 m distance
FeaturesMinimum operating time 10 h and Easy operation via keypad

 LD 400 is a simplified version of Leak detectors offered by CS Instruments, it is supplied with basic unit,  acoustic trumphet, focus tube & Noise proof headset. LD 400 can give colour identification of leakage depending on leakage rate. It is easy to use leak detector for compressed air line, gases vapour, Vaccum plants, door seals & refrigeration plants, etc.

Focus Tip-upto 0.5m

Acoustic Trumphet->0.5- 6m.

 

Request
Callback
Yes! I am interested

Inline Flow Sensor

Inline Flow Sensor
  • Inline Flow Sensor
Ask For Price
Product Price :Get Latest Price

Product Details:

Usage/ApplicationEnergy monitoring in compressed air/ other gases.
Model Name/NumberVA 521, VA 525
Measuring Range90 m3/h, 170 m3/h, 290 m3/h, 530 m3/h, 730 m3/h, 1195 m3/h
Measuring SectionDN 15, DN20, DN25, DN32, DN40, DN50
FeaturesNo inlet sections necessary - integrated flow straightener - Sensor unit can be removed

Inline flow sensor:-The ideal device for energy monitoring in compressed air and other gas systems with many consumers. Display values can be rotated by 180° in the display, e. g. when installing overhead.

Display shows 2 values at the same time:

• Actuall Flow in m³/h, l/min.
• Total consumption (meter reading) in m³, l, kg.

Models: VA 521- Compact inline flow meter for compressed air and other gas types, VA 525- Compact in-line flow sensor.
Request
Callback
Yes! I am interested

Flow Sensor with Integrated Measuring Section

Flow Sensor with Integrated Measuring Section
  • Flow Sensor with Integrated Measuring Section
Ask For Price
Product Price :Get Latest Price

Product Details:

Usage/ApplicationCompressed air, Nitrogen (N2), Argon (Ar), Carbon dioxide (CO2), Oxygen (O2), Nitrous oxide (N2O)etc
Model Name/NumberVA 520, VA 570
Measuring RangeMIN-20 m3/h upto 5380 m3/h depending upon the gas 7 speed of supply.
Measuring SectionDN15, DN20, DN25, DN32, DN40, DN50, DN65, DN80.
Features4 values in the display: Flow, total consumption, velocity, temperature. Units freely adjustable

Flow meter with newly developed evaluation electronics to record all measured values digitally.The measuring sections are available in flanged version or with R resp. NPT thread.
A special feature is the removable measuring head. So the measuring unit can be removed easily and quickly for calibration or cleaning purposes without having to dismount the measuring section intricately. During this period the measuring section is sealed by a closing cap (accessory). The screwing with centring device ensures that the sensor is positioned accurately in the center when screwing it into the measuring section Furthermore it grants an exact positioning in the flow direction. This avoids unnecessary measuring faults.